Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Innovation ; : 136-137, 2014.
Article in English | WPRIM | ID: wpr-975343

ABSTRACT

Background: The technique of pancreatoduodenectomy (PD) has evolved, andartery first’ approach was considered for the intraoperative early determinationof resectability for borderline resectable cases before the ‘point of no return’and avoidance of blood congestion resulted in the reduction of blood loss. Also,active application of energy device was useful for the reduced operative time andblood loss. Recently, 3D simulation for hepatobiliary pancreatic surgery has beenuseful and mandatory. In this presentation, we introduced our recent refinementsand advances for PD.‘Artery first’ approach and vessel sealing system for PD: ‘Artery first’ approachwere considered as six different methods as follows; 1) Superior approach, 2)Anterior approach, 3) Posterior approach, 4) Left posterior approach, 5) Right/medial uncinate approach and 6) Mesenteric approach. A while ago, wepreferably applied the mesenteric approach to PD, and also the combination ofthis approach with vessel sealing system (VSS) significantly reduced intraoperativeblood loss (Mesenteric approach with VSS, n=21 vs. non-‘Artery first’ approachwithout VSS, n=78; 320±174ml vs. 486±263ml, p<0.01).Modified de-rotation method as complete ‘Artery first’ approach: Most recently,for further refinement of operative procedure, we refined a right/medial uncinateand posterior approach as modified de-rotation method. Point of view in thismethod was the complete clockwise rotation of small intestinal mesenteryincluding ascending colon, in order to linearize from duodenum to jejunumand look at the direct front of superior mesenteric artery (SMA), vein (SMV) andsome branched jejunal vessels originated from SMA and SMV (Fig.). Thereby, inthe posterior view, the easy dissection of all pancreatic branch originated fromSMA can be done. This modified de-rotation method was possible to achieve thecomplete ‘Artery first’ approach.Preoperative 3D simulation of arterial and venous anatomy:Until now, we applied 3D volumetery software (SYNAPSE VINCENT®) aspreoperative simulation for hepatic resection. And recently, for evaluation of theposition relationship between arteries and veins surround pancreas head, weadopted this software before PD. As first step, arteries and veins are automaticallyidentified, and small vessels are manually traced on the axial CT view. Afterthat, 3D arterial and venous simulations are combined. Grasp of detailed vesselanatomy and its relationship using preoperative 3D simulation enable to safelyperform PD, even in young surgeons (operative time; young 512±49 vs. senior445±41 min, p<0.01), (blood loss; young 353±203 vs. senior 246±109 ml,p=0.16).Conclusion: Those refinements and advances are possible to safely and easilyperform pancreatoduodenectomy.

2.
Innovation ; : 136-137, 2014.
Article in English | WPRIM | ID: wpr-631163

ABSTRACT

Background: The technique of pancreatoduodenectomy (PD) has evolved, and artery first’ approach was considered for the intraoperative early determination of resectability for borderline resectable cases before the ‘point of no return’ and avoidance of blood congestion resulted in the reduction of blood loss. Also, active application of energy device was useful for the reduced operative time and blood loss. Recently, 3D simulation for hepatobiliary pancreatic surgery has been useful and mandatory. In this presentation, we introduced our recent refinements and advances for PD. ‘Artery first’ approach and vessel sealing system for PD: ‘Artery first’ approach were considered as six different methods as follows; 1) Superior approach, 2) Anterior approach, 3) Posterior approach, 4) Left posterior approach, 5) Right/ medial uncinate approach and 6) Mesenteric approach. A while ago, we preferably applied the mesenteric approach to PD, and also the combination of this approach with vessel sealing system (VSS) significantly reduced intraoperative blood loss (Mesenteric approach with VSS, n=21 vs. non-‘Artery first’ approach without VSS, n=78; 320±174ml vs. 486±263ml, p<0.01). Modified de-rotation method as complete ‘Artery first’ approach: Most recently, for further refinement of operative procedure, we refined a right/medial uncinate and posterior approach as modified de-rotation method. Point of view in this method was the complete clockwise rotation of small intestinal mesentery including ascending colon, in order to linearize from duodenum to jejunum and look at the direct front of superior mesenteric artery (SMA), vein (SMV) and some branched jejunal vessels originated from SMA and SMV (Fig.). Thereby, in the posterior view, the easy dissection of all pancreatic branch originated from SMA can be done. This modified de-rotation method was possible to achieve the complete ‘Artery first’ approach. Preoperative 3D simulation of arterial and venous anatomy: Until now, we applied 3D volumetery software (SYNAPSE VINCENT®) as preoperative simulation for hepatic resection. And recently, for evaluation of the position relationship between arteries and veins surround pancreas head, we adopted this software before PD. As first step, arteries and veins are automatically identified, and small vessels are manually traced on the axial CT view. After that, 3D arterial and venous simulations are combined. Grasp of detailed vessel anatomy and its relationship using preoperative 3D simulation enable to safely perform PD, even in young surgeons (operative time; young 512±49 vs. senior 445±41 min, p<0.01), (blood loss; young 353±203 vs. senior 246±109 ml, p=0.16). Conclusion: Those refinements and advances are possible to safely and easily perform pancreatoduodenectomy.

3.
Innovation ; : 8-12, 2013.
Article in English | WPRIM | ID: wpr-631143

ABSTRACT

INTRODUCTION: Recent technical innovation in liver surgery is remarkable. Now, for example, a preoperative 3D-simulation of the liver is a routine modality, and indispensable (or essential) for liver surgery. The aim of this presentation is to clarify various kinds of progresses and future perspective in liver surgery. PREOPERATIVE MODALITIES 1) One-stop shopping of 3D-simulation of the liver: We newly developed 3D-simulation using a software of SYNAPSE VINCENT Ver. 3.1 (Fujifilm Medical, Tokyo, Japan), in which biliary system is simultaneously reconstructed in one dynamic MD-CT. This technique avoids position error which occurred in 3D fusion image using another modality such as DIC–CT or MRCP, as well as unnecessary radiation exposure. 2) Assessment of partial functional reserve: We have reported new methods to astimate regional hepatic functional reserve using hepatocyte-phase of EOB-MRI (J Gastroenterol 2012), and fusion image of 3D-CT and asialoscintigraphy using 99m-Tc galactosyl human albumin. The method of EOB-MRI utilized character of hepatocyte-uptake of EOB through membrane transporters on hepatocytes. The other used fusion of both asialoscintigram of hepatic functional reserve and 3D-simulation by the above-mentioned software. Those techniques provided accurate estimation of partial functional volume, and help surgeons’ decision making of resection volume. INTRAOPERATIVE MODALITIES: 1) Navigation using iPad: navigation using iPad in which preoperative 3D-image data are uploaded in advance, tumor location, accurate and anatomical orientation can confirm in the operative field during operation. This technique enable not only operators also assistants or students to better understand precise anatomy. 2) Indocyanine green (ICG) fluorescent image-guided navigation: this technique using HyperEye Medical System (MIZUHO IKAKOGYO Co., Ltd. Tokyo, Japan) help us to confirm tattooing of target segment and parenchymal intersegmental plane, and detect hepatic tumors (metastatic and HCC) near liver surface as well as invisible tumor inside the liver. CONCLUSIONS: Various advancements such as preoperative 3D-simulation including partial functional reserve estimation and intraoperative navigation techniques enabled surgeons to easily and safely perform hepatic resection.

SELECTION OF CITATIONS
SEARCH DETAIL